Engineered for Uptime: The Worldwide Air Coolers Advantage

 

Manufacturing the next generation of industrial-grade air cooling solutions, optimized for the high-density and energy-critical demands of modern data centers.

The Need for Specialized Data Center Cooling

Data centers are mission-critical environments where heat management dictates performance and profitability. Our industrial heritage ensures that every Worldwide Air Cooler unit is not only highly efficient but built to run continuously, 24/7/365. We focus on two key metrics critical to your operation:

Critical Heat Load Management

Designed to handle extreme power densities and maintain precise temperature setpoints, ensuring zero thermal throttling for your servers.

Optimized PUE

Utilizing high-efficiency components like EC fans and advanced heat transfer surfaces to minimize Power Usage Effectiveness (PUE).

Our 4-Phase Manufacturing Process

Phase 1: Precision Engineering

The journey begins in the virtual realm, ensuring optimal performance before any metal is cut.

  • CFD Modeling: Advanced flow simulation for peak energy efficiency.
  • Component Selection: Sourcing durable, high-grade, corrosion-resistant materials.
  • Prototyping: Creation and validation in a simulated high-heat environment.

Phase 2: Core Fabrication & Assembly

Building the heart of the cooler with industrial-grade quality and meticulous attention to detail.

  • CNC Fabrication: Precision-cut enclosures for structural integrity and sealing.
  • Heat Exchanger: Meticulous assembly and leak-testing of cooling coils.
  • Fan Mounting: Installation of Variable Speed EC Fans for precise airflow control.

Phase 3: Smart Integration

The unit's intelligence is added, ensuring seamless operation within your Building Management System (BMS).

  • Structural Sealing: Final assembly of piping, wiring, and structural components.
  • Control Installation: Mounting and initial programming of the advanced PLC controller.
  • System Pre-Checks: Electrical continuity and control logic validation.

Phase 4: Factory Acceptance Testing (FAT)

Our commitment to reliability is validated by rigorous, unit-specific testing before shipment.

  • Thermal Performance: Verification of cooling capacity under full and partial load.
  • Acoustic Testing: Confirmation of low noise levels compliant with data center standards.
  • Certification: Comprehensive data logging and delivery of performance certificates.

Ready to Optimize Your Data Center Cooling?

Partner with Worldwide Air Coolers for cooling units engineered for resilience and efficiency.